BRWR


Bomb Resistant Waste Receptacles

Bomb Mitigation for High Traffic & High Value Facilities

What is this?

Our BRWR are engineered to mitigate blasts of large TNT equivalents . American Innovations, Inc. manufactures the only Bomb Resistant Waste Receptacles successfully tested to a reliable testing standard.


All our bomb receptacles were successfully tested at the Energetic Materials Research and Testing Center (EMRTC) located in Socorro, New Mexico. Live demonstrations were also conducted at the USMC HQ located in Quantico, Virginia.


These bomb receptacles can also integrate an Anti-Ramming Bollard feature without affecting their outward appearance, waste management functionality, or exposing the increased security function.


Why is this Needed?

Trash Receptacles, which are a necessity for waste management, pose a serious threat to Public Safety considering how easily they can conceal an explosive device planted by a terrorist. The trash receptacle becomes part of the attack and maximizes the intensity of the bomb by spraying shrapnel and fragmentation at great distances. It must also be understood that a terrorist attack utilizing ordinary trash receptacles and remote activated or time delayed explosive devices can be easily coordinated to strike multiple places simultaneously or in stages without exposing the terrorist who will most likely be located at a safe standoff distance


Customize & Make it Yours!

Your choices make it blend with your environment.


Add options to customize your solution to match

facility architecture, décor and brand.


No Publication of Deployment Location or Protection Criteria

Easy to Maintain and Keeps Your Facility's Custodial Needs Manageable

Highest Protection Ratings You Will Ever Find. We Even Encourage Random Testing!


Who Else Is Doing This?

Airports,Government Facilities, Malls and Stadiums, Museums, Train Stations, Military Bases, Amusement Parks, Courthouses, Bus Terminals, Corporate Facilities, Schools and Universities, City Streets, just to name a few!


Due to the sensitive nature of this technology, American Innovations, Inc. will not publicize or disclose specific deployment locations to the private sector. Federal, State, and Local government agencies along with the Department of Defense may request customer references.



Featured on the History Channel

Demonstrated at USMC HQ (Quantico, VA)
Tested at EMRTC (Socorro, NM)


How Does it Work?

  • Triple Wall Technology, tested to withstand various capacity explosions (Bottom Center, Sidewall Weld Seam, Sidewall Opposite Weld Seam, and Midpoint) without Horizontal Fragmentation.

  • Initial blast is contained horizontally and remaining blast energy is directed vertically.

  • Designed with no metal parts of container in the blast path to fragment and become airborne during an explosion. Stainless Steel Top remains attached to the waste receptacle.

  • Galvanized edges, walls and drains provide corrosion resistance in most environments.

  • Choose from anti-graffiti painted finishes or stainless steel.

  • Attractive and durable polished stainless steel top is standard on all models. Top will not discolor from tobacco products and can be cleaned and buffed again and again. Plastic liner accepts multiple garbage bags at the same time, which are easily removed when full. Attendant can easily remove a full bag to prevent an explosive being placed above containment area during peak usage.

  • Plastic liners are full capacity thirty (30) and forty (40) gallon, not nominal sizes.

  • Flexible internal drainage out of bottom or side. Spillage can also be stored internally for later clean up and wash down.

  • Easy on-site placement, leveling, and anchoring with single point pickup and stainless steel anchor, which resists over 4000 pounds of shear (horizontal) or tension (vertical) force.

  • Installation and Maintenance instructions included with every order. Technical assistance is also available at no charge via email or phone. On site supervision and/or installation services can be provided for a fee.

  • Americans with Disabilities Act (ADA) compliant.

  • Dimensions: 29" Diameter & 37.5" Height (39" with leveling legs extended).

  • Designed, built, and tested in the USA using only US purchased materials. Truly BERRY Compliant

  • Weight: Starting at 1400 lbs.

  • Custom Designed Lifting Tool is provided with every order. Moving and installing these receptacles is simplified with inexpensive, readily available equipment.




Accessories to Consider


Product Videos

EMRTC Testing Video of Guardian Model

EMRTC Testing Video of Protector Model

EMRTC Testing Video of Defender Model

Buyer Resources

Everyone can't be an expert at everything! We are here to help you select the best options, dot your "i's" and cross your "t's"


Let us help you from budgeting to deployment we are your best resource

Solicitation Recommendations

If you are required to publish a solicitation for bidding purposes, here is the only specification that will ensure fair competition without compromising the security of your facility and the people your bomb receptacles will protect.


Agency __ (Name) ___ is looking to purchase ____ (Quantity) ___ of Bomb Resistant Waste Receptacles. The actual quantity to be purchased may increase or decrease depending on the available budget.

Every vendor is required to submit their two highest rated receptacles and must include with their proposal detailed product specifications, installation instructions, pricing, and their estimated delivery lead-time. Product specifications shall include, at a minimum, dimensions, waste capacities available, finishes available, fluid collection and drainage options, steps required for removal of full waste bags and recommended maintenance.

If a vendor only offers one model with one level of force protection, they are welcome to submit that one model for consideration.

All proposals must include an official test report from a recognized US testing facility that defines; the type and amount of explosives used, the platform or type of surface their product was tested on, and the location(s) within their receptacle(s) the detonation test(s) were conducted. The test report must incorporate post detonation photos and the supporting video footage of the testing is also required.

Send Proposal to ___________________ and contact _______________ with any questions.

Security Notice: Never publicize the location(s) you will be installing bomb resistant waste receptacles and never publicize or share with any outside vendors the exact explosive containment ratings you are considering to or have decided to purchase. Doing so will compromise your security and place defenseless people in harms way.




Ask us about adding a random testing requirement. You will be glad you did!


Testing Criteria & Safety Issues

  • Why is it important that the explosive containment ratings for any bomb resistant trash receptacle you are considering to purchase not publicized on a website, brochure, or in a public tender?

    Button
  • Slide title

    An explosive containment rating is the amount of explosives that a bomb receptacle was successfully tested to contain during an explosion. By making this information publicly available, the terrorist will acquire the necessary intelligence to defeat your bomb receptacles.

    Button
  • Why must the Media not be informed that your facility has deployed bomb resistant trash receptacles? Why is it important that the explosive containment ratings for any bomb resistant trash receptacle you are considering to purchase not publicized on a website, brochure, or in a public tender?

    Button
  • Slide title

    This technology was developed to provide high traffic and high risk facilities with an edge over the terrorist who gather most of their intelligence through the media. By disclosing this information, you will enable them to coordinate a different method for executing a successful attack on your facility.

    Button
  • How quickly can a bomb receptacle be installed? What is the benefit of having the ability to anchor them quickly?

    Button
  • Slide title

    When using the proper tools, a bomb receptacle that integrates a single point anchoring system capable of withstanding a minimum of 4000 lbs. of shear (horizontal) and tension (vertical) force, can be installed by two people in less than 10 minutes. A significant cost per unit reduction once labor is factored in.

    Button

Share by: